home
company profile
contractors' pumps
sewage pumps industrial pumps
application reports references
general conditions of sales
press releases
  contact
  The Tsurumi Technical Library
  legal notice
  deutsche versionversion française
   


 
 

 
 

  
   

 
TRN

400V/50Hz

 

Dimensions:

  more Information...

The open rotor of the TRN series suctions a large volume of water for the motor power throughthe pump basket. This water is then mixed with air and distributed horizontally in all directionsthrough the channels of the guide ring.The top of the rotor is hollow and allows the air that has been suctioned in to fill the area aroundthe shaft seal so that it can mix with the water at the rotor. One consequence of this is that alayer of air is formed separating the shaft seal from the medium and thereby substantiallyincreasing the life of the shaft seal. Another effect is that the water that is suctioned in isoxygenated with tiny air bubbles, effectively aerating the waste water.

Standard Accessories:
  • Silencer & Valve Set

 
 
 

 





 
  

model

motor
output
kW

phase

r.p.m.

starting
method

air inlet
diameter
mm

max.
impeller
depth
m

no. of
outlets

dry
weight
kg

cable
length
m

32TRN2.75

0,75

3-ph.

3000

d.o.l.

32

3,5

6

55

10

32TRN21.5

1,5

3-ph.

3000

d.o.l.

32

3,5

6

55

10

50TRN42.2

2,2

3-ph.

1500

d.o.l.

50

3,6

6

140

10

50TRN43.7

3,7

3-ph.

1500

d.o.l.

50

4,0

6

150

10

50TRN45.5

5,5

3-ph.

1500

d.o.l.

50

4,0

6

170

10

80TRN47.5

7,5

3-ph.

1500

d.o.l..

80

4,5

6

190

10

80TRN412

12

3-ph.

1500

s.d.

80

6,0

6

200

10

80TRN417

17

3-ph.

1500

s.d.

80

6,0

6

220

20

100TRN424

24

3-ph.

1500

s.d.

100

6,0

8

460

20

150TRN440 40 3-ph 1500 s.d. 150 6,0 8 635 20
Dry weight of the pump without cable

 


Pressurised System


This is a method of deep layer aeration using
TSURUMI submersible aerators of the
TRN-series.
For example a nine meter deep tank may be
pressurised to a depth of six meters by the
action of a rotary blower and then the
remaining three meters may be treated by
the suction of the aerator.

The adoption of this system can greatly
decrease the power necessary by the
blower in order to aerate the same area.

 

Air Emission Volume-Water Depth Curve
(at 20°C, air emission value may vary ±5%)

Air Emission Volume-Water Depth Curve