230V/400V/50Hz

 

Dimensions:

  freestanding types

Titanium is used in all the wet metal parts of the TM pumps.
Titanium has a far stronger oxide film on its surface than stainless steel does. This prevents the pumps from being corroded in the seawater which has a very high chlorine ion concentration.
 

 
 
 

 





 
  

Discharge
Bore mm

Model

Motor
Output
kW

Phase

Head
max
m

Capa-
city
max
l/min

Starting
Method

Dry
Weight
kg 

Impeller
passage
mm

Cable
Length
m

40

40TM2.25S

0,25

single

9,0

240

condensor

6,7

10

10

40

40TM2.25

0,25

3-phase

9,0

240

d.o.l.

5,7

10

10

50

50TM2.4S

0,4

single

12,0

290

condensor

6,7

10

10

50

50TM2.4

0,4

3-phase

12,0

300

d.o.l.

6,6

10

10

50

50TM2.75

0,75

3-phase

15,0

350

d.o.l.

7,8

10

10

dry weight of the pump excluding cable

 
Item  Discharge bore (mm)  40 50
Pumping 
fluid
 Type of fluid Seawater
 Liquid temperature 0 ~ 40°C
Pump Components  Impeller Vortex
 Shaft Seal Double mechanical seal
 Bearing Sealed ball bearing
Materials  Impeller Resin (with glass fibre)
 Upper casing Resin (with glass fibre)
 Lower casing Resin (with glass fibre)
 Shaft seal 
 (mechanical seal)
Silicon Carbide in oil bath
Motor Type, Poles Dry-type submersible
induction motor, IP68,
2poles, 3000 r.p.m.
Insulation Class E 
Phase / Voltage Single-230V/3-phase 400V
Motor Protector (built-in) Circle Thermal cut-out
Lubricant Paraffine oil (ISO VG15)
Materials  Frame Titanium
 Shaft Titanium
 Cable Rubber, H07RN-F
Discharge Connection Special flange
 
Dimensions:   freestanding types