OM(A)
Sump pump
made of stainless
steel plate and fibre-reinforced plastic,
resistant to
corrosion.
..more information
 |
- discharge bore 32mm
- impeller
passage 10mm
- vortex impeller
- 230V, 110V
/single
phase/50Hz
- 2 poles
- motor output
0,15kW
- motor protector
- automatic
version
|
|
 |
POMA
Sump pump
made of stainless
steel plate and fibre-reinforced plastic,
resistant to
corrosion.
..more information
 |
- discharge bore
50mm
- impeller
passage 35mm
- vortex impeller
- 230V, 110V
/single
phase/50Hz
- 2 poles
- motor ou
tput
0,15kW
- motor protector
- automatic
version
|
|
 |
PU
Multi
purpose sewage
pump made of stainless
steel plate and fibre-reinforced plastic,
resistant to
corrosion.
..more information
 |
- discharge bore
50-80mm
- impeller
passage 35-46mm
- vortex impeller
- 230V single ph.
/
400V 3-ph. /50Hz
- 2 poles
- motor output
0,25-1,5kW
- motor protector
- automatic
version available
- guide rail
fitting optional
|
|
 |
U
A wide
pump casing
interior prevents
clogging by waste and
solid matters.
..more information
 |
- discharge bore
40-80mm
- impeller
passage 35-56mm
- vortex impeller
- 230V single ph.
/
400V 3-ph. /50Hz
- 2 poles
- motor output
0,25-3,7kW
- motor protector
- guide rail
fitting optional
|
|
 |
UX
Explosion proof
ATEX Ex II 2G Ex d IIB
A wide
pump casing
interior prevents
clogging by waste and
solid matters.
..more information
 |
- discharge bore 50-80mm
- impeller
passage 35-56mm
- vortex impeller
- 400V 3-ph. /50Hz
- 2 poles
- motor output 1,6-2,4kW
- motor protector
- guide rail
fitting optional
|
|
 |
UZ
The UZ
pump features
a vortex structure and
wide pump casing interior, preventing clogging by waste
and solid matter.
..more information
 |
- discharge bore 50-100mm
- impeller
passage 50-100mm
- vortex impeller
- 400V 3-ph. /50Hz
- 4 poles
- motor output 1,5-11kW
- motor protector
- guide rail
fitting optional
|
|
|

|
BZ
80mm solid passage.
A non-clog impeller
allows large diameter
of foreign matter with
respect to discharge bore. This ensures that waste water
and sewage are efficiently transferred.
..more information

|
- discharge bore
80-100mm
- impeller
passage 80mm
- non-clog
impeller
- 400V/3-phase/50Hz
- 4 poles
- motor output
1,5-11kW
- motor protector
- guide rail
fitting optional
|
|
 |
B
Proprietary impeller and
shaver mechanism
ensures that waste
water and sewage are
efficiently transferred.
..more information
 |
- discharge bore
50-100mm
- impeller
passage 19-53mm
- non-clog
impeller
- 400V
/3-phase/50Hz
- 2 poles / 4
poles
- motor output
0,4-7,5kW
- motor protector
- guide rail
fitting optional
|
|
 |
BX
Explosion proof
ATEX Ex II 2G Ex d IIB
Proprietary impeller and
shaver mechanism
ensures that waste
water and sewage are
efficiently transferred.
..more information
 |
- discharge bore 80-100mm
- impeller
passage 41-53mm
- non-clog
impeller
- 400V
/3-phase/50Hz
- 2 poles / 4
poles
- motor output 1,6 -
3,8kW
- motor protector
- guide rail
fitting optional
|
|
 |
C
A cutter
mechanism
ensures that fibrous
foreign matter is cut
up and sewage is
transferred without
clogging.
..more information
 |
- discharge bore
50-100mm
- impeller
passage 21-60mm
- non-clog
impeller with cutter
- 400V
/3-phase/50Hz
- 2 poles / 4
poles
- motor output
0,75-11kW
- motor protector
- guide rail
fitting optional
|
|
 |
CX
Explosion proof
ATEX Ex II 2G Ex d IIB
A cutter
mechanism
ensures that fibrous
foreign matter is cut
up and sewage is
transferred without
clogging.
..more information
 |
- discharge bore 80-100mm
- impeller
passage 43-70mm
- non-clog
impeller with cutter
- 400V
/3-phase/50Hz
- 2 poles / 4
poles
- motor output 1,6 -
3,8kW
- motor protector
- guide rail
fitting optional
|
|
 |
TM
Seawater
pump,
titanium is used in
all the wet parts.
..more information
 |
- discharge bore
40-50mm
- impeller
passage 10mm
- vortex impeller
- 230V single ph.
/ 400V 3-ph. /50Hz
- 2 poles
- motor output
0,25-0,75kW
- motor protector
|
|
 |
SFQ
Special
pump for
corrosive liquids,
austenitized stainless
steel is applied in
all wet parts.
..more information
 |
- discharge bore
50-80mm
- open impeller
- 400V/3-phase/50Hz
- 2 poles
- motor output
0,4-11kW
- motor protector
- guide rail
fitting optional
|
|
|

|
SQ
For use
with slightly
corrosive liquids,
uses liquid paraffin
as lubricant.
..more information
 |
- discharge bore
40-50mm
- open impeller
- 230V single ph.
/ 400V 3-ph. /50Hz
- 2 poles
- motor output
0,25-0,75kW
- motor protector
|
|
 |
BER
AERATOR
High oxygen dissolution
efficiency, strong
agitation effect.
..more information
 |
- non-clog
impeller
- 400V
/3-phase/50Hz
- 2 poles / 4
poles
- motor output
0,75-5,5kW
- motor protector
- guide rail
fitting optional
|
|
 |
TRN
AERATOR
High oxygen
dissolution efficiency,
strong convective
agitation effect.
..more information
 |
- air volume
7-630m³/h
-
subconvection 3,5-17m
- semi-open impeller
- 400V/3-phase/50Hz
- 2 poles / 4
poles
- motor output
0,75-40kW
- motor protector
|
|
 |
FHP
Only
supernatant water is
discharged without any
entrapment of sediments.
..more information
 |
- discharge bore
40-50mm
- non-clog
impeller
- 230V single ph.
/ 400V 3-ph. /50Hz
- 2 poles
- motor output
0,25-0,75kW
- motor protector
|
|
 |
FSP
Submersible scum
skimmer
..more information
 |
- discharge bore
50mm
- non-clog
impeller
- impeller
passage 16-22mm
- 400V
/3-phase/50Hz/2poles
- motor output
0,4-0,75kW
- motor protector
|