home
company profile
contractors' pumps
sewage pumps industrial pumps
application reports references
general conditions of sales
press releases
  contact
  The Tsurumi Technical Library
  legal notice
  deutsche versionversion française
   


 

  
   

KTV 
400V/50Hz

Use of new materials
has resulted in lighter
weight and even better
resistance to sandy water
than those of conventional
equivalents
 

Standard Acessessories:

  • 1 Cable 20m

  • 1 Threaded flange
    or hose coupling
    optionally

Dimensions, more information    

 


 

The KTVE-type is equipped with a new electrode type control system.
Pump operation is started when the water level rises and contacts the electrode.When the water-electrode-contact is lost the timer starts operating and after one minute pump operation is stopped.
 

 
 
 

 






 

Model

Discharge
Bore
mm

Motor
Output
kW

Rated
current
A

Phase

Head
max.
m

Capacity
max.
l/min

Starting
Method

Dry
Weight
kg
KTV (KTVE)

Max.
solid
handling
mm

Max.
water
depth
m

Cable
Length
m

KTV2-8

KTVE2.75

50 0,75

1,8

3-phase 15,0 320 d.o.l. 11,5 (12,0)

6

20

10
KTV2-15 KTVE21.5 50 1,5

3,3

3-phase 20,0 420 d.o.l. 20,5 (21,0)

8,5

50

20
KTV2-22 KTVE22.2 50 2,2

4,3

3-phase 24,0 525 d.o.l. 23,0 (23,5)

8,5

50

20
KTV2-37H

--

50 3,7

7,4

3-phase 33,8 500 d.o.l. 36,0 (--)

8,5

50

20
KTV2-37 KTVE33.7 80 3,7

7,4

3-phase 26,5 830 d.o.l. 36,0 (36,5)

8,5

50

20
KTV3-55 KTVE35.5 80 5,5

11,0

3-phase 35,0 980 d.o.l. 46,5 (47,0)

8,5

50

20
dry weight of the pump without cable
 
 
Item  Discharge bore (mm)  50 80
Pumping 
fluid
 Type of fluid Rain water, Ground water, 
Sand carrying water
 Liquid temperature 0 ~ 40°C
Pump Components  Impeller Semi-vortex
 Shaft Seal Double mechanical seal
 Bearing Shielded ball bearing
Materials  Impeller Synthetic rubber (0,75kW)
Ductile iron casting (>0,75kW)
Casing Synthetic rubber
 Shaft seal
 (mechanical seal)
Silicon Carbide in oil bath
Motor Type, Poles Dry-type submersible induction motor,
IP68, 2poles, 3000 r.p.m.
Insulation Class E
Phase / Voltage Three-phase, 400V
Motor Protector (built-in) Circle thermal cut-out
Lubricant Turbine Oil (ISO VG32)
Materials  Frame Aluminium alloy casting
 Shaft Stainless Steel EN-X30Cr13/X6Cr13
 Cable Rubber, H07RN-F
Discharge Connection Threaded flange
 
 

Dimensions, more information  
 

In the event of abrasive and corrosive utilization, stronger wear and tear will take place naturally in certain components. In this regard, please pay attention to our website
www.tsurumi-europe.com/englisch/applications