Cologne/Bonn airport connection, Germany |
| |
|
|
|
 |
|
The
Project:
Connection of the newly built road for Cologne/Bonn airport
Executing Company
Heitkamp GmbH, Wayss&Freytag AG,
Trapp GmbH
The Problem:
Maintainance of water level in a rainwater storage basin at the building
site. |
| |
|
|
| Our
Solution:
Installation of 2 submersible pumps KTVE21.5 and KTVE22.2. The advantage
here is in the integrated level control unit via electrodes. A separate
floater cable does not have to be laid. The space required is determined
by the diameter of the pump. In contrast to floaters, electrodes do not
have to be readjusted. The level can be varied without any difficulty by
mounting a screw. |
|
 |
| |
|
|
In the
event of abrasive and corrosive utilization, stronger wear and tear will
take place naturally in certain components. With regards to the above
application wear and tear can take place mainly in impeller, suction
plate, shaft sleeve, oil ring, mechanical seal and pump casing.
Depending on the working conditions the lifetime of those parts might
vary significantly and can be shorter than the legal warranty period.
In this regard, please pay attention to our
general conditions of sales
(www.tsurumi-europe.com/english/GCS.htm) that we also